DVT Solutions, LLC 30 GHz TDR Probe

Home

Data Sheets

Application Notes

Inst. Compatibility

Lecroy

Tektronix

Agilent

PicoSecondPulseLab

BERTScope

Using Accessories

Hand Probing

Attaching GigaProbes™ to Micro-positioners

Setting Signal-Signal Pitch

50 Ohm Probe Setup

DeskTop Macro-Lens

TDR Probe Stations

Specifications

Conductive Diamonds

Customers

On-line Purchase

Contact Us

Site Map

 

TEKTRONIX TDR Systems
 GigaProbes(tm)
Compatability

Link: http://www.tek.com/
Tektronix TDS8200 Application
Tektronix TDS8200 and Gigaprobes(tm)



In the picture on the Left a TDS8200 Tektronix TDR system is used with two Gigaprobes™ and a Probe Station to model a T Cable assembly. TDR/TDT waveforms were taken and converted to S-parameters using IConnect. The S-parameters were ported to ADS and converted to a behaveral model.
 
 
The GigaProbes™ is compatible with the The DSA8200 digital serial analyzer sampling oscilloscope. Use your Gigaprobes™ in the 100 ohm differential or 50 ohm single ended mode for interconect analysis applications - TDR performance, S-parameter bandwidth using the Tektronix IConnect software.  The GigaProbes are also compatable with all Legacy TDR Sampling oscilloscopes like the 11800 series.  Order sampling head extenders to get the TDR sampling heads close to the device under test so you can use short cables to reduce the TDR risetime degradation.
 
The new 80E10 and 80E08 TDR
The Gigaprobes(tm) can be directly attached to the new 80E10 and 80E08 TDR modules

Applications

  1. Loss Tangent Measurements for Differential and Single Ended Transmission Lines
  2. Failure Analysis of PCB with or without Components Mounted
  3. (TDR) Impedance Testing of IC Package, Cable, PCB, Backplane

When GigaProbes(tm) are used with IConnect® from TDA Systems, a Tektronix Company:

  • Create accurate interconnect impedance measurements, S11 and S21 S-Parameter, eye diagram and mask tests
  • Create accurate Hspice models of connectors, IC packages, PCB’s, cables from TDR/T waveforms
  • Direct measurement of IC package and connector self and mutual inductance/capacitance
  • Faster Fault isolation
IConnect
Tektronix IConnect

Copyright 2006 Brian Shumaker DVT Solutions 650 593-7083

DVT Solutions, LLC